Room sensor NL-iVOC with relay is used to monitor air quality inside buildings and power control ventilation (HVAC) systems according to current levels of air pollution. The sensor can be effectively used in offices, classrooms, restaurants, kitchens, fitness…

  • measures VOC
  • close to the human perception of odors
  • compatibility with CO2 standard
  • 2x analog voltage/current output
  • 2x output relay – 2x NO/C
  • cascade switching

Description

Built-in advanced iVOC sensor is sensitive to volatile organic substances typically contained in the stuffy air – gaseous metabolic products of human bodies and other gaseous pollutants such as formaldehyde, cooking vapors, fumes from paints, varnishes, adhesives, detergents, etc. that CO2 sensor does not detect. NL-iVOC sensor detects gaseous pollutant substances in the air that are the main reason for ventilation.

Sensor NL-iVOC approximates to human perception of air quality. The output of the sensor is calibrated as equivalent to a standard CO2 sensor. Measurement of the relative humidity is based on the principle of capacitive polymer sensor. The sensor has built-in two separate analog outputs – one for the actual concentration of VOC and the other for the current relative humidity. If the sensor contains 2 relays can be set two switching modes: standard (always one relay switched according to one quantity), a cascade mode (according to a selected quantity switch two relays with different levels of switching). Cascade switching, for example, can be used to switch power air conditioning units. The two rotary switches can be independently set the level at which the corresponding relay switches. Sensor can efficiently manage ventilation and heat recovery units, based on current air quality. By three LED indicators can be easily checked the current air quality. Preferred eco level means good indoor air quality needed to achieve a sense of well-being and at the same time can reduce energy costs for heating or air conditioning.

ParameterValue 
Supply voltage range14 V – 40 V DC or 18 V – 30 V AC
Average consumption0,5W
Ingress protectionIP20
iVOC* measuring range450 – 2000ppm
iVOC* relay – hysteresis100ppm
RH measuring range0 – 100 %RH
RH accuracy 20 – 80 %± 3 %RH
RH accuracy 0 – 100 %± 6 %RH
RH switching hysteresis5 %RH
Max. switching voltage250/30V AC / V DC
Max. switching current5/5A AC /A DC
Working humidity no condensing5 – 95 %RH
Working temperature0 to +50°C
Storage temperature-20 to +50°C
Expected lifetimemin. 10years
Dimensions90x80x31mm

Datasheet